0=RAIDCFG Command successful!
1=Error! Incorrect Syntax.
2=Failure!
3=Illegal operation
4=Unsupported operation
5=Device not found
6=Format boot drive illegal
7=Buffer too small
8=Virtual Disk contains boot partition. Use force option to delete
9=Init boot drive failed
10=Format boot drive failed
11=Cannot write boot drive
12=Unsupported RAID value
13=Invalid RAID configuration
14=Span length not in range
15=RAID 1 failed
16=Exactly 2 array disks are required to create a RAID 1 virtual disk
17=Unsupported stripe size value
18=RAID 5 only
19=RAID 5 error
20=A minimum of 3 array disks are required to create a RAID 5 virtual disk			
21=RAID 0 failed
22=RAID 10 failed
23=RAID 50 failed
24=RAID 5 not supported
25=RAID 50 not supported
26=Size too small for given RAID type
27=Wrong number of disks for RAID 1-concatenated 
28=Insufficient space to mirror disks
29=Create Mirror not supported
30=Disk in use
31=Disk Lock operation failed
32=Disk locked
33=Disk Unlock operation failed
34=Disk Unlocked
35=Disk failed on rebuild
36=Hot Spare not free
37=Disk Diagnostic failed
38=Disk Rebuild failed
39=Disk Format failed
40=Cancel of Disk Diagnostic Failed
41=Cancel of Disk Rebuild failed
42=Cancel of Disk Format failed
43=Assign Hot Spare failed
44=Disk too Small for Hot Spare
45=Unassign Hot Spare failed
46=Prepare Disk for Removal failed
47=Disk Online failed
48=Disk Offline failed
49=UnMount Operation failed
50=Mount Operation failed
51=Cannot Format Array Disk
52=Bad chunk size	
53=Invalid disk
54=Virtual disk not found
55=Virtual disk locked
56=Drive in use
57=Reached maximum physical size
58=Reached maximum count of virtual disks
59=There is not enough free space on the array disk(s) to allow the operation to complete; the size of the virtual disk is too large; or communication to the array disk(s) has been lost
60=Select the array disks that are part of a similar type of virtual disk (T10 protection and encryption capability) or the array disks that are not part of any virtual disks.
61=Invalid Parameter
62=Failed drive cannot be added
63= The controller cannot support the number of array disks that you have selected. Choose a smaller number.
64=Delete virtual disk failed. Controller busy
65=Delete virtual disk failed
66=Create virtual disk failed
67=Create virtual disk failed. Controller busy
68=Create virtual disk failed. Failed to map virtual disk to operating system disk. 
69=Create virtual disk failed. Failed to map virtual disk to operating system disk. 
70=Virtual disk initialization failed.
71=Virtual disk initialization failed. Controller busy
72=Virtual disk reconstruction failed. Controller busy
73=Virtual disk resynching failed. Controller busy
74=Flush Virtual disk's cache failed on controller. 
75=Virtual disk partition specified not found.
76=Unsupported cache policy value
77=Unsupported write policy value
78=Unsupported read policy value
79=Cancel initialization on virtual disk failed
80=Cancel reconstruction on virtual disk failed
81=Cancel resynchronization on virtual disk failed
82=The maximum number of virtual disks that can be created has been reached
83=The new virtual disk must use only the remaining free space on the array disks used in the last virtual disk you created. Select all array disks that are used in the last virtual disk you created.
84=You have selected an array disk that is in a degraded or failed state. Choose another array disk. 
85=Delete the last created virtual disk first
86=Virtual disk initialized for use and no override requested
87=Virtual disk type requested is invalid for the attempted operation.
88=Virtual disk Move operation failed.  Cannot rename, virtual disk is already in use.
89=Failover invalid
90=Virtual disk resynching
91=Virtual disk resynch failed
92=Virtual disk reconstruct failed
93=Cannot format a virtual disk that contains a boot or system partition
94=Cannot initialize a virtual disk that contains a boot or system partition
95=Virtual disk Copy failed.
96=Virtual disk mirror set required.
97=Virtual disk Create - Read-only failed
98=Virtual disk Create - Read-write failed
99=Virtual disk - Clear-to-zero failed
100=Virtual Disk Requires Non Multilevel.
101=Virtual Disk Promote Operation failed.
102=Specified virtual disk has no drive letter assigned to it
103=Cannot expose virtual disk
104=Cannot reconfigure virtual disk
105=Cannot stop the reconfiguration of the virtual disk.
106=SMART report count not supported
107=Operations on hidden virtual disks are not allowed. 
108=Virtual disk is in use
109=The virtual disk is in use. It cannot be reconfigured at this time. 
110=Virtual disk operation is temporarily unavailable.  Initialization in progress.
111=Virtual disk operation is temporarily unavailable.  Reconstruction in progress.
112=Virtual disk operation is temporarily unavailable.  Rebuild in progress.
113=Virtual disk operation is temporarily unavailable.  Check Consistency in progress.
114=Specified virtual disk too small
115=Virtual disk operation not supported.  Size too small.
116=Operation is temporarily unavailable. Space in use.
117=Cannot reconfigure to the given RAID level
118=Cannot reconfigure from current RAID level to the given RAID level
119=One of the array disks selected for the virtual disk is already in use
120=Virtual disk operation not supported.  Cannot use non-RAID disk.
121=Controller Read Configuration failed
122=Controller Write Configuration failed
123=Controller cache flush failed
124=Enable alarm on controller failed
125=Disable alarm on controller failed
126=Quiet alarm on controller failed
127=Controller failed to perform the task
128=Specified bus not found for controller
129=Call to set cache mode on the controller failed
130=Unexpected controller error
131=Controller out of memory
132=Invalid controller state
133=Controller failed
134=Controller busy
135=Controller does not exist
136=Controller name is invalid
137=Controller is iterated
138=Rename of virtual disk was not successful
139=The controller was not able to erase the file system from the specified virtual disk
140=The controller was not able to add space to the specified concatenation set
141=The controller was not able to get the status of the specified mirror set
142=The controller was not able to set the requested failover space
143=The controller cannot get the failover space information
144=Controller cannot unmirror the specified virtual disk
145=The controller could not split the specified virtual disk
146=The controller could not lock the specified virtual disk
147=Controller IO paused
148=Command not supported on this controller
149=Controller does not recognize parameter symbol
150=Controller Battery Recondition failed
151=Controller Get disk signature failed
152=Controller Read Flags failed
153=Controller Set Flags failed
154=Controller Remove Snap Shot failed
155=Controller not supported
156=Controller device initialization failure
157=Partner controller already opened read-write
158=No partner controller found
159=The virtual disk is not valid for requested operation
160=Cannot communicate with controller
161=Set operation failed
162=Operation to update error count of SMART device has failed
163=Operation to clear error count of SMART device has failed
164=Driver could not execute
165=Cannot delete virtual disk
166=Cannot set temperature probe. Invalid value entered.
167=Cannot set enclosure tag. Invalid value entered.
168=Cannot set enclosure alarm
169=Temperature probe value out of range
170=Cannot set cache mode
172=Data will be lost on the secondary disk and a reboot will be forced
173=Cluster Services (MSCS) is running.  Deleting a virtual disk that contains a cluster resource can result in unpredictable errors or system hangs (quorum disk).  You should shut down cluster services before deleting cluster resources.  Are you sure you want to proceed?
174=Cannot perform Create Virtual Disk or Delete Virtual Disk while the other server in a cluster is online.  Please shut one of the servers down and retry the operation.
176=Invalid array disks or failover drives selected for reconfigure/create operation. Please make sure that all array disks and failover drives associated with the virtual disk are selected.
177=The maximum number of partitions have already been created on one of the selected array disk(s).Each array disk can hold portions (partitions) of up to  virtual disks. This virtual disk cannot be created because one or more array disk(s) have reached the  partition limit.
178=The virtual disk is in use. Please close any applications that use the virtual disk and unmount any file systems that reside on the virtual disk.
179=The firmware version is not supported. Please update the firmware from http://support.dell.com.
180=The specified device does not have enough free space to be used as failover space for the specified virtual disk.
181=The operation failed. Please rescan the controller and retry the operation. 
182=The operation cannot be performed while a task is running on the specified virtual disk.
183=The specified virtual disk has no dead disk segments. 
184=The operation cannot be performed at this time.  The firmware can recondition a battery that has a Degraded or Power Low state.  The firmware will not recondition a battery that is functioning normally or that has a Ready, Failed or Missing state.
185=The version of the controller firmware installed on your system does not support this operation. 
186=There are no disks of the correct type available to be assigned as a hot spare.
187=There are no disks of sufficient size available to be assigned as a hot spare.
188=There are no disks of the correct type and sufficient size available to be assigned as a hot spare.
189=The Create Virtual Disk task was successful but the operating system may not be aware of the new virtual disk.
191=The import of foreign configurations is complete. Some configurations could not be imported.
192=Enable alarm command failed. The enclosure processor is busy or a firmware download is in progress.
193=Disable alarm command failed. The enclosure processor is busy or a firmware download is in progress.
194=Quiet alarm command failed. The enclosure processor is busy or a firmware download is in progress.
195=An error occurred while resetting a temperature probe.
198=Cannot assign more than sixteen dedicated hot spare per virtual disk.
199=HotSpares unsupported on this Controller.
200=No array disks found!
201=Invalid Virtual Disk ID!
202=RAID Type & Size are required to create a virtual disk. Ensure that the RAID type and the size are correct.
203=Invalid Environment command!
204=File is not writeable!
205=Setting Environment Variable Command failed!
206=Filename is not provided!
207=Invalid Strict option! Please provide a valid number between 1 and 100.
208=Span depth is not needed for this RAID type.
209=Array disk(s) cannot be part of virtual disk(s) and also be hotspares.
210=Cannot have silent and logfile switch with the same command.
211=Invalid array disk(s)!
212=Invalid failover disk(s)!
213=Creation of a virtual disk on this RAID controller requires the use of the entire disk space of the array disks. The size or -sz parameter is not needed.
214=Invalid size given! size=max or -sz=max is not supported for this RAID controller.
215=The value given for envname or -envn is null or too long.
216=Invalid virtual disk size!
217=The strict option provided failed! Virtual disk is not created.
218=Unable to determine optimum size for Virtual disk. Ensure that the array disks are of the same protocol (i.e. SAS, SATA, SCSI). If there is a mismatch of the array disks then the RAIDCFG will not be able to determine the optimum size. In addition, also ensure that there is enough drives and size available for the specified virtual disk.
219=One or more array disks selected to create virtual disk or hotspare doesn't have enough disk space. Please make sure that all the array disks and failover drives selected have enough free space.
220=The number of array disks provided is incorrect for the requested RAID Type! RAID 1 requires exactly 2 array disks, RAID 5 requires at least 3 array disks, RAID 10 requires at least 4 array disks, RAID 50 requires at least 6 array disks, RAID 6 requires at least 4 array disks and RAID 60 requires at least 8 array disks.
221=No free array disks found!
222=No global failover disks found!
223=One or more array disks selected for the virtual disk has foreign configuration.
224=Error in opening the file.
225=SAS 5/IR, SAS 6/IR, H200 and SW RAID requires atleast two physical disks to create RAID 0 or RAID 1.
226=No Foreign configuration present in the controller.
227=The virtual disk cannot be created on the physical disks you selected. Possible reasons include:unsupported mix of SAS and SATA protocol type disks, unsupported mix of SSD and HDD media disks
228=Unsupported array disks selected for VD creation.
229=Setting stripe size is not supported in this controller.
230=Invalid VirtualDisk(VD) name specified. VD name can have alphanumeric characters [A-Z,a-z,0-9,_,-] only. Also, VD name size must be less than or equal to 15 characters
231=Error occurred while setting virtual disk as boot disk
232=Error occurred while setting name for virtual disk
233=Couldn't get boot virtual disk
234=PCIe Link Speed could not be set for the RAID controller. Please check if the controller has the capability to set/change its PCIe link speed
235=PCIe Link Speed can be set to either 2 or 3 i.e. PCIe Generation 2.0 or 3.0
236=PCIe Link Speed could not be retrieved for this RAID controller.Please check if the controller has the PCIe link speed capability
237=Please reset the controller before doing any further operation.
238=Boot Mode can be set to 0 (BIOS stop on error), 1 (BIOS continue on error), 2 (Headless continue on error)
239=Boot Mode could not be set for the RAID controller.
240=Enable Auto Import can be set to 0 (No) or 1 (Yes).
241=Cannot discard the preserved cache because a foreign configuration is present on the controller. Use '-ignoreconfig' or '-igncfg'  to discard the cache.
1000=Enable Auto Import property could not be set for the RAID controller.
1001=Invalid array disk list.
1002=Source or destination disk is in invalid state. Make sure that the source disk is in online state, destination disk is in ready state, and the size of the destination disk is greater than or equal to the size of the source disk.
1003=Operation not allowed. Cannot set the array disk state to online.  
1004=Operation not allowed. Cannot set the array disk state to offline.
1005=Invalid encrypted array disk list for the instant secure erase operation.
1006=Sector drives 512B and 4KB must not be combined while creating a virtual disk.
1007=Hot spare sector size for the virtual disk is not matching.
1008=sectorsize parameter is not found.
1009=Warning! Cannot assign global hotspare. Input array disk can act as a hotspare only for virtual disks with matching sector size (4KB or 512B), T10 PI capability and encryption capability. Use "-force" option to discard the warning.
1010=Force option is invalid for this operation on the specified controller.
1011=Input values for vdiskprotectioninfo and vdpi are 1 and 0.
1012=vdiskprotectioninfo or vdpi option is not available on the controller.
1013=Input array disks or hotspares are not PI-capable.
1014=Creation of RAID 10 virtual disk with Uneven Span failed.
1015=Spanlength is not required for creating a RAID10 virtual disk on this controller.
1016=Unsupported operation. RAID 6 and RAID 60 virtual disks which are T10 PI enabled do not support Slow Initialize. 
1017=Operation is not supported. The specified controller does not have encryption capability.
1018=Operation is not supported. Encryption key is not present on the specified controller.
1019=The specified array disks or hotspares do not have encryption capability.
1020=The specified controller does not have a locked foreign configuration.
1021=Invalid passphrase.
1022=Input values for secureflag and sf are 1 and 0.
1023=Unsupported operation. Preserved cache is not present on the controller.
1024=Invalide Key Id
1025=Encryption key is already set for the controller.
1026=Cannot delete the encryption key because secure virtual disk is present. 
1027=The passphrase is invalid or old.
1028=Cannot increase the virtual disk size due to lack of free space or due to the presence of partial virtual disks on the same set of array disks.
1029=The percentage value of virtual disk size must be in the range 1-100.
1030=Error! Cannot discard the preserved cache. Use '-force' option to discard the cache.
1031=Cannot create a new virtual disk because preserved cache is present on the controller. To clear the cache, either import the related virtual disks or discard the cache.
1032=Unsupported RAID value. The expand virtual disk size operation is allowed only on RAID-0, RAID-1, RAID-5, and RAID-6.